BACnet BB2-7030 Dokumentacja Strona 19

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 130
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 18
NEW!
729
NETWORK & WIRELESS
NETWORK & WIRELESS
13
WE MAKE IT EASY.
kele.com 888-397-5353 USA
March 2014
BACNET/IP AND LON/IP ROUTER
L-IP SERIES
WIRING
LIP-xECTB
LIP-xxECRB
LIP-xxECTB
10/100Base-T
(RJ45)
-
12-35 VDC
12-24 VAC
+
Termination
(L-Term)
CEA-709
CEA-852
4568 15 16 17
POWEREthernet
Serial Terminal
RESET
LINK
ACT
ACT
CNIP
Ethernet
Server
POWER
STAT
US
40
B
C
F
E
D
G
H
FT
Connectors
CEA-709 4 Input EARTH GND port 1
5 Input B port 1
6 Input A port 1
Ethernet 8 10/100Base-T (RJ45)
POWER 15 Power supply input EARTH GND
16 Power supply input MINUS
17 Power supply input PLUS
Do NOT connect to
EARTH GND
SERIAL 40 EIA-232 (DB9 male)
Buttons
RESET Reset
STATUS Send service pin message
Status LEDs
B Green flashing fast Traffic on port 1
Green flashing at
1 HZ
Red permanent
Red flashing fast
Green
Yellow
Red
Flashing at 1 Hz
OFF
Port not commissioned
CEA-709 port damaged
Traffic overload on port 1
IP port is fully functional
IP port functional but
config. is not up-to-date
IP port in non-functional
IP port is not commissioned
IP port is not active
C
D Green Ethernet link
E Green flashing Ethernet traffic
F Green BBMD enabled
G Green Power
H OFF Normal operation
10/100Base-T
(RJ45)
-
12-35 VDC
12-24 VAC
+
Termination
(L-Term)
CEA-709
Loop
Side 1
CEA-852
4568 15 16 17
POWEREthernet
Serial Terminal
RESET
LINK
ACTPRIM
ACT
CNIP
Ethernet
Server
POWER
STATUS
40
B
A
C
F
E
D
G
H
FT
123
FT
CEA-709
Loop
Side 2
Connectors
CEA-709 1 Do not connect
2 Input B loop side 2
3 Input A loop side 2
CEA-709 4 Input EARTH GND port 2
5 Input B loop side 1
6 Input A loop side 1
Ethernet 8 10/100Base-T (RJ45)
POWER 15 Power supply input EARTH GND
16 Power supply input MINUS
17 Power supply input PLUS
Do NOT connect to
EARTH GND
SERIAL 40 EIA-232 (DB9 male)
Buttons
RESET Reset
STATUS Send service pin message
Status LEDs
A Green Device is active
Off
Orange
Red
Green flashing fast Traffic on CEA-709 loop
Green flashing at
1 HZ
Red permanent
Red flashing fast
Green
Yellow
Red
Flashing at 1 Hz
OFF
Device is inactive (standby)
Problem with twin router
Device is inactive due to
error
Port not commissioned
CEA-709 port damaged
Loop open/Traffic overload
IP port is fully functional
IP port functional but
config. is not up-to-date
IP port in non-functional
IP port is not commissioned
IP port is not active
B
C
D Green Ethernet link
E Green flashing Ethernet traffic
F Green BBMD enabled
G Green Power
H OFF Normal operation
10/100Base-T
(RJ45)
-
12-35 VDC
12-24 VAC
+
Termination
(L-Term)
CEA-709
Port 1
CEA-852
4568 15 16 17
POWEREthernet
Serial Terminal
RESET
LINK
ACT
ACT
CNIP
Ethernet
Server
POWER
STAT
US
40
B
C
F
E
D
G
H
FT
123
FT
CEA-709
Port 2
Connectors
CEA-709 1 Input EARTH GND port 2
2 Input B port 2
3 Input A port 2
CEA-709 4 Input EARTH GND port 1
5 Input B port 1
6 Input A port 1
Ethernet 8 10/100Base-T (RJ45)
POWER 15 Power supply input EARTH GND
16 Power supply input MINUS
17 Power supply input PLUS
Do NOT connect to
EARTH GND
SERIAL 40 EIA-232 (DB9 male)
Buttons
RESET Reset
STATUS Send service pin message
Status LEDs
A Green flashing fast Traffic on port 2
Green flashing at
1 HZ
Red permanent
Red flashing fast
Green flashing fast Traffic on port 1
Green flashing at
1 HZ
Red permanent
Red flashing fast
Green
Yellow
Red
Flashing at 1 Hz
OFF
Port not commissioned
CEA-709 port damaged
Traffic overload on port 2
Port not commissioned
CEA-709 port damaged
Traffic overload on port 1
IP port is fully functional
IP port functional but
config. is not up-to-date
IP port in non-functional
IP port is not commissioned
IP port is not active
B
C
D Green Ethernet link
E Green flashing Ethernet traffic
F Green BBMD enabled
G Green Power
H OFF Normal operation
Przeglądanie stron 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 129 130

Komentarze do niniejszej Instrukcji

Brak uwag

MasterCool Pompy podręczniki użytkownika

Zaczynanie od 0-9

Kliknij na poniższy alfabet, aby przejść do pełnej listy modeli zaczynających się od tej litery

Modele Rodzaj dokumentu
90060 1.5 CFM VACUUM PUMP (TWO STAGE)
Instrukcja Użytkownika   Mastercool 90060 1.5 CFM VACUUM PUMP (TWO STAGE) User Manual, 4 strony
90066-2V-110 6 CFM VACUUM PUMP (TWO STAGE)
Instrukcja Użytkownika   Mastercool 90066-2V-110 6 CFM VACUUM PUMP (TWO STAGE) User Manual, 4 strony
90066-A 6 CFM VACUUM PUMP (SINGLE STAGE)
Instrukcja Użytkownika   Mastercool 90066-A 6 CFM VACUUM PUMP (SINGLE STAGE) User Manual, 2 strony
90067 7.5 CFM VACUUM PUMP (TWO STAGE)
Instrukcja Użytkownika   Mastercool 90067 7.5 CFM VACUUM PUMP (TWO STAGE) User Manual, 4 strony
90070-2V-110 10 CFM VACUUM PUMP (TWO STAGE)
Instrukcja Użytkownika      Mastercool 90070-2V-110 10 CFM VACUUM PUMP (TWO STAGE) User Manual, 8 strony